Answers are grounded in this paper and cite their sources.
The choice of switching frequency for pulsewidth modulation single-phase inverters, such as those used in grid-connected photovoltaic application, is usually a tradeoff between reducing the total harmonic distortion (THD) and reducing the switching loss. This paper discusses an approach to minimize the switching loss while meeting a given THD requirement using variable switching frequency schemes (switching schemes with the switching frequency varying within a fundamental period). An optimal switching scheme is proposed based on time-domain current ripple analysis and the calculus of variations. The analysis shows that, to meet the same THD requirement, the optimal scheme has a significant saving on switching loss, compared to the fixed switching frequency scheme and the hysteresis control scheme, in addition to other benefits such as reduced peak switching loss and a spread spectrum of the current harmonics. The optimal scheme has been implemented in a prototype and the experimental results have verified the theoretical analysis. Also, a straightforward design method for designing filter inductors for single-phase converters is provided based on the time-domain current ripple analysis.
No takes yet. Share an insight, caveat, or question.
Mao et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: