Key result
Automated pulse pressure variation values ≥13% were present in 38% of measurements in post-cardiac surgery patients, and higher PPV correlated with negative fluid balance (P<0.001).
Why the study?
What is the prevalence of likely fluid responsiveness (PPV ≥ 13%) and its hemodynamic associations in cardiac surgery patients on mandatory ventilation?
Observational (n=30)
No
What is the prevalence of likely fluid responsiveness (PPV ≥ 13%) and its hemodynamic associations in cardiac surgery patients on mandatory ventilation?
Automated PPV values indicating likely fluid responsiveness are common in post-cardiac surgery patients and correlate logically with other hemodynamic and ventilation parameters.
Supports PPV as a potential fluid responsiveness marker in ventilated post-cardiac surgery patients; leaves open whether PPV-guided management improves outcomes.
BACKGROUND: Pulse pressure variation (PPV) is an accepted measure of intravascular filling. It can now be estimated automatically. However, there is limited knowledge of the epidemiology and associations of such estimates in cardiac surgery patients. METHODS: We conducted a pilot prospective observational study of the epidemiology and associations of automatically estimated PPV in 30 cardiac surgery patients admitted to the intensive care unit of a tertiary hospital. The study was conducted in June and July 2010. We collected automated monitor-estimated PPV values every 15 minutes during mandatory ventilation in patients after cardiac surgery. We simultaneously collected data on all relevant haemodynamic values, hourly fluid balance, tidal volume (V(T)) and peak airway pressure. We made a total of 205 measurements on 30 patients. A PPV value ≥ 13% was selected as defining a likely fluid responsiveness (FR) state. Clinicians were not informed of the study. RESULTS: PPV values ≥ 13% were present in 38% of measurements, and the average duration of this physiological state was 38 minutes per patient. Higher PPV values correlated with negative fluid balance (P < 0.001), lower mean pulmonary arterial pressure (P = 0.018), lower cardiac index (P = 0.013), higher peak airway pressure (P < 0.001) and higher V(T) (P < 0.001). CONCLUSIONS: In a tertiary ICU, among patients who had recently had cardiac surgery, automated PPV values in the likely FR range were present in over a third of measurements. Correlations with other haemodynamic and ventilation values were logical and expected.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2011) conducted an observational in Post-cardiac surgery (n=30). Automated pulse pressure variation (PPV) was evaluated on Proportion of measurements with PPV ≥ 13% (likely fluid responsiveness state). Automated pulse pressure variation values ≥13% were present in 38% of measurements in post-cardiac surgery patients, and higher PPV correlated with negative fluid balance (P<0.001).