Key result
Pre-procedural CT planning and CT-fluoroscopy image fusion for fluoroscopic overlay of landmarks was feasible in all 5 complex percutaneous mitral interventions.
Why the study?
Does pre-procedural CT planning with CT-fluoroscopy image fusion optimize trans-septal access in patients undergoing percutaneous mitral interventions?
Case Report (n=4)
Does pre-procedural CT planning with CT-fluoroscopy image fusion optimize trans-septal access in patients undergoing percutaneous mitral interventions?
CT-fluoroscopy image fusion is feasible and provides additional 3D guidance to optimize trans-septal access during complex percutaneous mitral interventions.
Supports feasibility of CT-fluoroscopy fusion in complex mitral cases; leaves open whether it optimizes transseptal access or safety.
Background Recent evolution of transcatheter mitral devices and interventions has mandated the need for further optimizing trans-septal access technique with respect to its precise location and distance from the mitral valve annulus. Methods Based on the individual procedural context, "ideal" trans-septal access site was planned in multi-slice CT images. In addition, relevant landmarks such as mitral annulus, para-valvular leak site, left atrial appendage (LAA) ostium were electronically marked. CT-fluoroscopy image fusion was performed using a commercially available software after acquiring two fluoroscopic images at-least 30° apart. Manual refinement of image fusion was performed by aligning structures such as a prosthetic valve or mitral annular calcification, when necessary. Results Between June and October 2016, a total of five procedures (n = 3 Mitral paravalvular leak, n=2 Mitraclip®) were performed in four patients using trans-esophageal echocardiography (TEE) and CT image fusion guidance. Fluoroscopic overlay of landmarks including the optimal trans-septal puncture site from pre-procedural CT images was feasible in all five procedures. Median time for CT-fluoroscopy image fusion was 4:08 minutes. Median time for left atrial access was 7:00 minutes. Median (range) fluoroscopy time and total procedural dose-area-product were 29.9 minutes (15.1–77.5) and 16,638 microGy-m 2 (9464–18,990) respectively. Conclusion In addition to real-time TEE imaging, pre-procedural CT planning, image fusion and overlay of relevant landmarks enhances 2D fluoroscopy and provided additional 3D image guidance. Seamless integration of such multi-modality image information can help further optimize steps such as trans-septal access for complex mitral interventions.
No takes yet. Share an insight, caveat, or question.
Neill et al. (2018) conducted a case report in Complex mitral interventions (mitral paravalvular leak, Mitraclip) (n=4). Pre-procedural CT planning and CT-fluoroscopy image fusion was evaluated on Feasibility of fluoroscopic overlay of landmarks. Pre-procedural CT planning and CT-fluoroscopy image fusion for fluoroscopic overlay of landmarks was feasible in all 5 complex percutaneous mitral interventions.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: