Why the study?
Does CT-derived 3D-augmented fluoroscopy provide feasible, safe, and accurate guidance for transseptal puncture in patients undergoing atrial fibrillation ablation?
Does CT-derived 3D-augmented fluoroscopy provide feasible, safe, and accurate guidance for transseptal puncture in patients undergoing atrial fibrillation ablation?
CT-derived 3D-augmented fluoroscopy is a feasible, safe, and highly accurate method for guiding transseptal puncture during atrial fibrillation ablation procedures.
Provides preliminary support for CT-3D fluoroscopy in transseptal puncture; requires prospective validation before clinical adoption.
BACKGROUND: Transseptal puncture for left atrial (LA) access is still mainly performed using fluoroscopy and transesophageal or intracardiac echocardiography. We present an easily applicable approach for the guidance of transseptal puncture that uses the combination of a 3D-mapping system and CT-derived 3D-overlayed anatomy. METHODS AND RESULTS: A computer tomographic (CT) LA-angiography was performed in n = 65 patients prior to a scheduled atrial fibrillation ablation procedure. The CARTO3 (Biosense Webster, Diamond Bar, CA, USA) segmentation tool was used to create a 3D-reconstruction of cardiac anatomy and the spine. The CARTO UNIVU module was then used to overlay and register the segmented 3D-anatomy onto fluoroscopy. The 3D-reconstructed spine and cardiac anatomy were congruently aligned to their fluoroscopic counterparts in fluoroscopic views. The feasibility of the technique, its safety, and accuracy (assessed as contour offsets between 3D-overlay and angiographic LA anatomy) were evaluated. Overlay registration accuracy was analyzed by CARTO3 registration matrices. Transseptal puncture was feasible without complications in all 65 patients using the new 3D-overlay technique. Three-dimensional-overlay contour offsets were 1.6 ± 1.2 mm in left PV, 1.7 ± 1.2 mm in right PV, and 1.3 ± 1.0 mm in the LA roof region. Overlay registration accuracy was 4.9 ± 2.7 mm. The average time needed for anatomy segmentation was 204 ± 61 seconds, time needed for overlay registration was 18 ± 8 seconds. CONCLUSIONS: Three-dimensional-augmented fluoroscopy is feasible, safe, and easy to apply as guidance for transseptal puncture and demonstrates a high level of accuracy.
No takes yet. Share an insight, caveat, or question.
Bourier et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: