Key result
CT-merged 3D mapping enables 100% successful transseptal puncture with zero complications in ACHD.
Why the study?
Attempts to perform low- or zero-fluoroscopy transseptal puncture using 3D mapping in adults with congenital heart disease who have previously undergone surgical or interventional treatment are limited.
Is transseptal puncture guided by 3D electroanatomical mapping superimposed with cardiac CT anatomy feasible and safe for achieving zero- or low-fluoroscopy access in adults with repaired congenital heart disease undergoing left-sided arrhythmia ablation?
Cohort (n=45)
No
Is transseptal puncture guided by 3D electroanatomical mapping superimposed with cardiac CT anatomy feasible and safe for achieving zero- or low-fluoroscopy access in adults with repaired congenital heart disease undergoing left-sided arrhythmia ablation?
Superimposing 3D electroanatomic mapping with pre-procedural cardiac CT enables safe and effective zero- or low-fluoroscopy transseptal puncture in adults with complex, surgically or interventionally altered interatrial septa from congenital heart disease.
Answers are grounded in this paper and cite their sources.
Extends zero-fluoroscopy transseptal techniques to repaired ACHD; leaves open confirmation in randomized trials.
Aims: The widespread use of three-dimensional (3D) mapping systems and echocardiography in the field of cardiac electrophysiology has made it possible to perform transseptal punctures (TSP) with low or no fluoroscopy. However, such attempts in adults with congenital heart disease (ACHD) who have previously undergone surgical or interventional treatment are limited. Therefore, we sought to explore the feasibility and safety of an approach to perform zero- or low-fluoroscopy TSP in ACHD patients undergoing left atrial cardiac ablation procedures. Methods and results: This study included 45 ACHD patients who underwent TSP for ablation of left-sided tachycardias (left atrium or pulmonary venous atrium). Computed tomography (CT) of the heart was performed in all patients prior to ablation. 3D mapping of the right-sided heart chambers before TSP was used to superimpose the registered anatomy, which was subsequently used for the mapping-guided TSP technique. TSP was performed with zero-fluoroscopy in 27 patients, and the remaining 18 patients had a mean fluoroscopy exposure of 315.88 ± 598.43 μGy.m2 and a mean fluoroscopy duration of 1.9 ± 5.4 min. No patient in this cohort experienced TSP-related complications. Conclusion: Our study describes a fluoroscopy-free or low-dose fluoroscopy approach for TSP in ACHD patients undergoing catheter ablation of left-sided tachyarrhythmias who had been previously treated surgically or interventionally due to congenital heart defects. By superimposing 3D electroanatomic mapping with cardiac CT anatomy, this protocol proved to be highly effective, feasible and safe.
No takes yet. Share an insight, caveat, or question.
Guan et al. (2023) conducted a cohort in Adults with congenital heart disease (ACHD) undergoing catheter ablation of left-sided tachyarrhythmias (n=45). Transseptal puncture guided by 3D electroanatomic mapping (CARTO) superimposed with cardiac CT anatomy was evaluated on Feasibility (successful single 3D-guided transseptal puncture) and safety (TSP-related complications). 3D electroanatomic mapping merged with CT guided transseptal puncture achieved 100% success (27/45 zero-fluoroscopy) with 0% complications in 45 ACHD patients.
Synapse has enriched 10 related papers. Consider them for comparative context: