Key result
Intracardiac echocardiography-guided transseptal punctures for fluoroless ablation of left-sided tachycardias were highly effective, with a 0.2% failure rate and a 1.9% overall complication rate.
Why the study?
The study aimed to evaluate the efficacy and safety of entirely ICE-guided transseptal punctures in patients undergoing fluoroless catheter ablation of left-sided tachycardias.
Does ICE-guided transseptal puncture allow safe and effective fluoroless catheter ablation of left-sided tachycardias in adult and pediatric patients?
Observational (n=524)
No
Does ICE-guided transseptal puncture allow safe and effective fluoroless catheter ablation of left-sided tachycardias in adult and pediatric patients?
Entirely ICE-guided transseptal punctures for fluoroless catheter ablation are highly successful and safe, though caution is needed in patients with CIEDs due to lead dislocation risk.
Answers are grounded in this paper and cite their sources.
Supports ICE-guided fluoroless ablation as a viable approach for left-sided tachycardias; leaves open the need for randomized trials to confirm safety.
Introduction Integration of intracardiac echocardiography (ICE) and 3D electroanatomic mapping (EAM) system allows transseptal punctures (TSP) without the use of fluoroscopy. Compared to fluoroscopy, ICE provides better visualization of the anatomy relevant to TSP and early recognition of complications. The aim was to evaluate efficacy and safety of entirely ICE- guided TSPs in patients who underwent fluoroless catheter ablation of left-sided tachycardias. Methods and results Consecutive 524 adult and pediatric patients referred to our institution from July 2014 to December 2019 were analyzed. Patients with cardiac implantable electronic devices (CIEDs) were also included. All procedures were performed with ICE-guided TSP combined with 3D EAM. Adverse events fol-lowing TSP and within 30 days of the procedure were analyzed. Altogether 949 TSPs (363 double punctures, 76.5%) were performed in 586 fluoroless ablation procedures: 451 (77%) were ablation of atrial fibrillation or atypical flutter, 75 (12.8%) of left-sided accessory pathway, 33 (5.6%) of ventricu-lar tachycardia, and 27 (4.6%) of focal atrial tachycardia. Forty-six (7.8%) procedures were performed in pediatric population and 36 procedures (6.1%) in patients with CIED. Only 2 TSPs were unsuc-cessful (2/949, 0.2%). Overall procedural complication rate was 1.9% (11/586 procedures). There was only 1 TSP related pericardial tamponade (2/949, 0.2%). In CIED patients there was 1 lead dislo-cation following TSP. Conclusion Entirely ICE-guided TSPs for different left-sided tachycardias can be safely and effectively performed in adult and pediatric population without the use of fluoroscopy. However, caution is advised in CIED patients due to possible lead dislocation risk.
No takes yet. Share an insight, caveat, or question.
ek et al. (2020) conducted an observational in Left-sided tachycardias (n=524). Intracardiac echocardiography-guided transseptal puncture was evaluated on Unsuccessful transseptal punctures. Intracardiac echocardiography-guided transseptal punctures for fluoroless ablation of left-sided tachycardias were highly effective, with a 0.2% failure rate and a 1.9% overall complication rate.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: