Key result
Fluoroless transseptal puncture using intracardiac echocardiography in pediatric patients had a mean procedure time of 22.2 minutes, with no significant difference compared to fluoroscopic guidance.
Why the study?
Does fluoroless transseptal puncture under ICE guidance maintain safety and procedural time compared to fluoroscopic guidance in pediatric patients undergoing SVT ablation?
Cohort
No
Does fluoroless transseptal puncture under ICE guidance maintain safety and procedural time compared to fluoroscopic guidance in pediatric patients undergoing SVT ablation?
Fluoroless transseptal puncture using ICE guidance is safe and feasible in pediatric patients without significantly increasing procedural time compared to fluoroscopic approaches.
Supports feasibility of fluoroless ICE-guided TS in pediatric SVT ablation; leaves open randomized trials before practice change.
BACKGROUND: Fluoroless transseptal (TS) puncture may represent the final step toward elimination of fluoroscopy in pediatric supraventricular tachycardia ablation in normal hearts. We aimed to demonstrate the safety and feasibility of fluoroless TS puncture in pediatric patients and compare procedural timing with the fluoroscopic approach. METHODS: We performed a retrospective cohort analysis of all TS procedures performed without fluoroscopy at our institution; fluoroless TS procedures were performed under intracardiac echocardiography (ICE) guidance after the creation of a 3D electroanatomic map and identification of fossa ovalis (FO) on 3D map. TS procedure times reported are the time from sheath insertion (8.5F short sheath for ICE catheter and SL-1 for TS needle) to the time of confirmed left atrial access. Prior TS procedures performed by the same operator utilizing a combination of ICE and fluoroscopy and by a second operator utilizing fluoroscopic guidance alone were used for comparison. RESULTS: Fluoroless TS puncture was performed in nine patients (mean age 13.8 years); the site of TS puncture was within 2 mm of the FO identified on the EA map. The mean TS procedure time was 22.2 minutes (range 10-45). There was no significant difference in TS procedure times between the three groups. There were no complications related to any TS procedure. CONCLUSION: Fluoroless TS procedures utilizing ICE can safely be performed in pediatric patients without adding substantial procedural times compared with those utilizing fluoroscopic guidance.
No takes yet. Share an insight, caveat, or question.
Clark et al. (2017) conducted a cohort in Pediatric supraventricular tachycardia. Fluoroless transseptal puncture vs. Fluoroscopic guidance (with or without intracardiac echocardiography) was evaluated on Transseptal procedure time. Fluoroless transseptal puncture using intracardiac echocardiography in pediatric patients had a mean procedure time of 22.2 minutes, with no significant difference compared to fluoroscopic guidance.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: