Key result
3D mapping-guided transseptal puncture cuts fluoroscopy time by ~1 minute compared to ICE guidance.
Why the study?
Both 3D mapping systems and intracardiac echocardiography (ICE) help localize the fossa ovalis and reduce fluoroscopy during transseptal puncture (TSP) for left atrial ablation, motivating a direct comparison of safety and efficacy between 3D-guided and ICE-guided TSP techniques.
Does 3D mapping system-guided transseptal puncture provide comparable safety and efficacy while reducing fluoroscopy time compared to intracardiac echocardiography (ICE)-guided transseptal puncture in patients undergoing left atrial catheter ablation?
Cohort (n=216)
Yes
Does 3D mapping system-guided transseptal puncture provide comparable safety and efficacy while reducing fluoroscopy time compared to intracardiac echocardiography (ICE)-guided transseptal puncture in patients undergoing left atrial catheter ablation?
3D electroanatomic mapping-guided transseptal puncture is as safe and effective as intracardiac echocardiography (ICE)-guided transseptal puncture for left atrial ablation, offering minimal fluoroscopy exposure without the added cost of an ICE catheter.
Answers are grounded in this paper and cite their sources.
3D mapping may reduce fluoroscopy during transseptal puncture without added risk; extends observational data but leaves open need for randomized confirmation.
INTRODUCTION: Transseptal puncture (TSP) is routinely performed for left atrial ablation procedures. The use of a three-dimensional (3D) mapping system or intracardiac echocardiography (ICE) is useful in localizing the fossa ovalis and reducing fluoroscopy use. We aimed to compare the safety and efficacy between 3D mapping system-guided TSP and ICE-guided TSP techniques. METHODS: We conducted a prospective observational study of patients undergoing TSP for left atrial catheter ablation procedures (mostly atrial fibrillation ablation). Propensity scoring was used to match patients undergoing 3D-guided TSP with patients undergoing ICE-guided TSP. Logistic regression was used to compare the clinical data, procedural data, fluoroscopy time, success rate, and complications between the groups. RESULTS: Sixty-five patients underwent 3D-guided TSP, and 151 propensity score-matched patients underwent ICE-guided TSP. The TSP success rate was 100% in both the 3D-guided and ICE-guided groups. Median needle time was 4.00 min (interquartile range [IQR]: 2.57-5.08) in patients with 3D-guided TSP compared to 4.02 min (IQR: 2.83-6.95) in those with ICE-guided TSP (p = .22). Mean fluoroscopy time was 0.2 min (IQR: 0.1-0.4) in patients with 3D-guided TSP compared to 1.2 min (IQR: 0.7-2.2) in those with ICE-guided TSP (p < .001). There were no complications related to TSP in both group. CONCLUSIONS: Three-dimensional mapping-guided TSP is as safe and effective as ICE-guided TSP without additional cost.
No takes yet. Share an insight, caveat, or question.
Chokesuwattanaskul et al. (2022) conducted a cohort in Left atrial arrhythmias (mostly atrial fibrillation) undergoing left atrial catheter ablation (n=216). 3D mapping system-guided transseptal puncture (CARTO 3) vs. Intracardiac echocardiography (ICE)-guided transseptal puncture was evaluated on Transseptal puncture fluoroscopy time (minutes) (p=<0.001). 3D mapping-guided transseptal puncture achieved 100% success with 0% complications while reducing mean fluoroscopy time compared to ICE guidance.
Synapse has enriched 10 related papers. Consider them for comparative context: