Key result
The CARDIAN deep learning approach correctly detected 69.94% of end-diastolic frames in intravascular ultrasound sequences within a 66.7 ms tolerance, outperforming expert analysts and conventional methods.
Why the study?
Cardiac cycle changes and catheter motion impact accurate IVUS volumetric quantification, requiring accurate end-diastolic frame detection typically identified retrospectively by human analysts.
Does the CARDIAN neural network approach improve end-diastolic frame detection accuracy in IVUS sequences compared to expert analysts?
Does the CARDIAN neural network approach improve end-diastolic frame detection accuracy in IVUS sequences compared to expert analysts?
Absolute Event Rate: 69.94% vs 29.02%
The CARDIAN neural network approach provides accurate and reproducible automated end-diastolic frame detection in IVUS sequences, outperforming expert human analysts.
May streamline IVUS analysis workflows; leaves open impact on diagnostic accuracy or outcomes.
Introduction: Changes in coronary artery luminal dimensions during the cardiac cycle can impact the accurate quantification of volumetric analyses in intravascular ultrasound (IVUS) image studies. Accurate ED-frame detection is pivotal for guiding interventional decisions, optimizing therapeutic interventions, and ensuring standardized volumetric analysis in research studies. Images acquired at different phases of the cardiac cycle may also lead to inaccurate quantification of atheroma volume due to the longitudinal motion of the catheter in relation to the vessel. As IVUS images are acquired throughout the cardiac cycle, end-diastolic frames are typically identified retrospectively by human analysts to minimize motion artefacts and enable more accurate and reproducible volumetric analysis. Methods: In this paper, a novel neural network-based approach for accurate end-diastolic frame detection in IVUS sequences is proposed, trained using electrocardiogram (ECG) signals acquired synchronously during IVUS acquisition. The framework integrates dedicated motion encoders and a bidirectional attention recurrent network (BARNet) with a temporal difference encoder to extract frame-by-frame motion features corresponding to the phases of the cardiac cycle. In addition, a spatiotemporal rotation encoder is included to capture the IVUS catheter's rotational movement with respect to the coronary artery. Results: With a prediction tolerance range of 66.7 ms, the proposed approach was able to find 71.9%, 67.8%, and 69.9% of end-diastolic frames in the left anterior descending, left circumflex and right coronary arteries, respectively, when tested against ECG estimations. When the result was compared with two expert analysts' estimation, the approach achieved a superior performance. Discussion: These findings indicate that the developed methodology is accurate and fully reproducible and therefore it should be preferred over experts for end-diastolic frame detection in IVUS sequences.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2023) studied Obstructive coronary artery disease (n=6). CARDIAN (bidirectional attention network) vs. Expert analysts and conventional image-based approach (LM) was evaluated on Correctly detected end-diastolic frames within a 66.7 ms tolerance (GoP recall). The CARDIAN deep learning approach correctly detected 69.94% of end-diastolic frames in intravascular ultrasound sequences within a 66.7 ms tolerance, outperforming expert analysts and conventional methods.