Key result
Very late drug-eluting stent thrombosis was associated with a significantly higher eosinophil fraction in aspirated thrombi (8.2%) compared to early (4.3%) and late (5.5%) stent thrombosis.
Why the study?
Is very late drug-eluting stent thrombosis associated with higher eosinophil fractions in aspirated thrombi compared to early or late stent thrombosis?
Observational (n=48)
Single-blind
Yes
Is very late drug-eluting stent thrombosis associated with higher eosinophil fractions in aspirated thrombi compared to early or late stent thrombosis?
Very late drug-eluting stent thrombosis is associated with a higher eosinophil fraction in aspirated thrombi, suggesting localized hypersensitivity as a potential underlying mechanism, while evidence of neoatherosclerosis was relatively uncommon.
Answers are grounded in this paper and cite their sources.
May implicate hypersensitivity in very late DES thrombosis; hypothesis-generating and should not change practice.
BACKGROUND: Localized hypersensitivity reaction, delayed arterial healing, and neoatherosclerosis inside the stent have been suggested as the underlying pathologic mechanisms of very late stent thrombosis (VLST) of drug-eluting stent (DES). The present study sought to explore the prevalence of inflammatory cell infiltrates and evidence for fragments of atherosclerotic plaques in the aspirated thrombi in patients with DES VLST. METHODS AND RESULTS: From April 2004 to September 2012, 48 patients with stent thrombosis (ST) of DES underwent thrombus aspiration with retrieved material sufficient for the histopathologic analysis; early ST (EST, within 30 days): N = 17, late ST (LST, between 31 and 365 days): N = 7, and very late ST (VLST, >1 year): N = 24. Eosinophil fraction in the aspirated thrombi was significantly higher in patients with VLST (8.2±5.7%) as compared with those with EST (4.3±3.0%) and LST (5.5±3.8%) (P = 0.03). Eosinophil fraction in the aspirated thrombi was significantly higher in 12 VLST patients with angiographic peri-stent contrast staining (PSS) and/or incomplete stent apposition (ISA) by intravascular ultrasound than in 12 VLST patients without PSS or ISA (10.6±6.1% versus 5.8±4.1%, P = 0.03). Evidences for fragments of atherosclerotic plaques in the aspirated thrombi were observed only in 3 (13%) out of 24 patients with DES VLST. CONCLUSIONS: Eosinophil fraction in the aspirated thrombi was significantly higher in patients with DES VLST as compared with those with EST and LST. Evidences for fragments of atherosclerotic plaques were relatively uncommon in patients with DES VLST.
No takes yet. Share an insight, caveat, or question.
Yamaji et al. (2014) conducted an observational in Drug-eluting stent thrombosis (n=48). Very late stent thrombosis (>1 year) vs. Early (≤30 days) and late (31-365 days) stent thrombosis was evaluated on Eosinophil fraction in the aspirated thrombi (p=0.03). Very late drug-eluting stent thrombosis was associated with a significantly higher eosinophil fraction in aspirated thrombi (8.2%) compared to early (4.3%) and late (5.5%) stent thrombosis.