Key result
A continuous blood pressure measurement system using dual PPG sensors and a neural network achieved a mean accuracy of 98.22% for systolic and 95.58% for diastolic blood pressure.
Why the study?
Does a continuous blood pressure measurement platform using dual PPG sensors and a BPNN accurately estimate blood pressure in Asian participants?
Does a continuous blood pressure measurement platform using dual PPG sensors and a BPNN accurately estimate blood pressure in Asian participants?
A novel continuous blood pressure measurement platform using dual PPG sensors and a BPNN demonstrated high accuracy for estimating systolic and diastolic blood pressure in an Asian cohort.
Answers are grounded in this paper and cite their sources.
May support wearable dual-PPG BP monitoring in Asian adults; hypothesis-generating and requires larger validation before clinical use.
This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography (PPG) sensors and a back propagation neural network (BPNN) that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators. The proposed platform measured the signal changes in PPG and converted them into physiological indicators, such as pulse transit time (PTT), pulse wave velocity (PWV), perfusion index (PI), heart rate (HR), and pulse wave analysis (PWA); these indicators were then fed into the BPNN to calculate blood pressure. The hardware of the experiment comprised 2 PPG components (i.e., Raspberry Pi 3 Model B and analog-to-digital converter [MCP3008]), which were connected using a serial peripheral interface. The BPNN algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure (SBP) and diastolic blood pressure (DBP). To increase the robustness of the BPNN model, this study input data of 100 Asian participants into the training database, including those with and without cardiovascular disease, each with a proportion of approximately 50%. The experimental results revealed that the mean and standard deviation of SBP were <a:math xmlns:a="http://www.w3.org/1998/Math/MathML" id="M1"><a:mn>2.23</a:mn><a:mo>±</a:mo><a:mn>2.24</a:mn><a:mtext> </a:mtext><a:mtext>mmHg</a:mtext></a:math> , with a mean squared error of 3.15 mmHg. The mean and standard deviation of DBP was <c:math xmlns:c="http://www.w3.org/1998/Math/MathML" id="M2"><c:mn>3.5</c:mn><c:mo>±</c:mo><c:mn>3.53</c:mn><c:mtext> </c:mtext><c:mtext>mmHg</c:mtext></c:math> , with a mean squared error of 4.96 mmHg. The proposed real-time blood pressure measurement system exhibited a mean accuracy of 98.22% and 95.58% for SBP and DBP, respectively.
No takes yet. Share an insight, caveat, or question.
Yen et al. (2021) studied Cardiovascular disease (50% of cohort) (n=100). Continuous blood pressure measurement platform using dual PPG sensors and BPNN was evaluated on Systolic and diastolic blood pressure estimation accuracy. A continuous blood pressure measurement system using dual PPG sensors and a neural network achieved a mean accuracy of 98.22% for systolic and 95.58% for diastolic blood pressure.