Key result
A 3D-electroanatomical mapping-based ablation strategy targeting slow pathway elimination reduced AVNRT recurrence to 1.7% compared to 14.3% with a conventional fluoroscopic approach.
Why the study?
Slow pathway ablation for AVNRT can result in complete elimination or modification with ambiguous benefits, and the clinical outcomes of a 3D-EAM-based strategy targeting complete elimination versus conventional fluoroscopy were unclear.
Does 3D-EAM-guided slow pathway elimination improve procedural outcomes and reduce recurrence in patients with AVNRT compared to conventional fluoroscopic slow pathway modification?
Observational (n=102)
No
Does 3D-EAM-guided slow pathway elimination improve procedural outcomes and reduce recurrence in patients with AVNRT compared to conventional fluoroscopic slow pathway modification?
Answers are grounded in this paper and cite their sources.
A 3D-EAM-guided strategy targeting complete slow pathway elimination in AVNRT is safe, reduces radiation exposure, and significantly lowers long-term recurrence rates compared to conventional fluoroscopic modification.
Background Slow pathway (SP) ablation, in the context of atrioventricular node reentrant tachycardia (AVNRT) treatment could result in either complete elimination or only modification of the SP with ambiguity regarding associated benefits. Three‐dimensional electroanatomical mapping (3D‐EAM) may be used adjunctively aiming to complete SP elimination. Our purpose was to compare a 3D‐EAM‐based strategy targeting SP elimination to the conventional fluoroscopic approach with respect to clinical outcomes. Methods One hundred and two consecutive AVNRT patients (36 males, mean age 53.2 ± 13.7 years) underwent in two successive periods a conventional fluoroscopic ablation approach ( n = 42) or a 3D‐EAM‐guided ablation focusing on complete SP elimination ( n = 60). Results Several procedural parameters improved with 3D‐EAM use, including fluoroscopy time (2.4 ± 4.7 min vs. 13 ± 4.5 min), dose‐area product (1061 ± 3122 μGy × m 2 vs. 5002 ± 3032 μGy × m 2 ) and slow pathway elimination frequency (95% vs. 50%, all p < .001). Procedural time was slightly prolonged in the 3D‐EAM group (101 ± 31 min vs. 87 ± 24 min, p = .013). Two major complications occurred in the conventional group. Altogether, over a mean follow‐up of approximately 2.7 years, recurrence occurred in 6 of 42 (14.3%) in the conventional group as compared to 1 of 62 (1.7%) in the EAM‐based group ( p = .019). In the Kaplan–Meier analysis, time‐to‐event was significantly longer for the EAM‐based patients ( p < .030). Moreover, the EAM‐based strategy was associated with less redo procedures' rates (9.5% in the non‐EAM group vs. 0% in the EAM group, p = .026). Conclusions The present study showed that an EAM‐based SP elimination strategy is not only feasible and safe but it is also accompanied by improved clinical outcomes in the setting of AVNRT ablation.
No takes yet. Share an insight, caveat, or question.
Tsiachris et al. (2022) conducted an observational in Atrioventricular node reentrant tachycardia (AVNRT) (n=102). 3D-electroanatomical mapping (3D-EAM) guided ablation vs. Conventional fluoroscopic ablation was evaluated on AVNRT recurrence (p=0.019). A 3D-electroanatomical mapping-based ablation strategy targeting slow pathway elimination reduced AVNRT recurrence to 1.7% compared to 14.3% with a conventional fluoroscopic approach.
Synapse has enriched 10 related papers. Consider them for comparative context: