Key result
Embolic protection device use during saphenous vein graft intervention was associated with improved post-procedural TIMI 2/3 flow (OR 2.38; 95% CI 1.51-3.74; P<0.001).
Why the study?
Does embolic protection device use improve post-procedural TIMI flow and reduce mortality or TVR in patients undergoing saphenous vein graft intervention?
Cohort (n=1,359)
Does embolic protection device use improve post-procedural TIMI flow and reduce mortality or TVR in patients undergoing saphenous vein graft intervention?
Answers are grounded in this paper and cite their sources.
The use of embolic protection devices during saphenous vein graft intervention is associated with improved post-procedural TIMI flow and reduced 1-year target vessel revascularization, supporting current guideline recommendations.
BACKGROUND: Embolic protection devices (EPDs) have been designed and introduced to reduce distal embolization and peri-procedural myocardial infarction during saphenous vein graft (SVG) intervention. Current guidelines give a class I recommendation to EPD use during SVG intervention when technically feasible. However, the routine use of these devices has recently been debated. METHODS: We analyzed 1,359 patients undergoing isolated SVG intervention between 2008 and 2013 in the British Columbia Cardiac Registry. We analyzed (a) post-procedural TIMI flow; and (b) target vessel revascularization (TVR) and mortality at 1 and 2 years. RESULTS: EPD use was an independent predictor of post-procedural TIMI 2/3 flow (OR = 2.38, 95% CI: 1.51-3.74, P < 0.001). At 1 year, EPD use was an independent predictor for lower TVR (HR = 0.35, 95% CI: 0.14-0.85, P = 0.021) and a trend towards lower mortality (HR = 0.45, 95% CI: 0.18-1.10, P = 0.082). These associations were lost at 2 years where EPD use was not predictive of mortality (HR = 0.62, 95% CI: 0.33-1.17, P = 0.144) or TVR (HR = 0.70, 95% CI: 0.41-1.17, P = 0.176). These findings were confirmed in propensity-matched and inverse probability treatment weighted analyses. CONCLUSIONS: In this analysis of patients undergoing SVG intervention, EPD use was a strong predictor for improved post-procedural TIMI flow. Whilst EPD use was associated with lower TVR and a trend for lower mortality at 1 year, these associations were lost at 2 years. These findings would appear to support the use of EPD for SVG intervention.
No takes yet. Share an insight, caveat, or question.
Iqbal et al. (2015) conducted a cohort in Saphenous vein graft (SVG) intervention (n=1,359). Embolic protection device (EPD) use vs. No EPD use was evaluated on Post-procedural TIMI 2/3 flow (OR 2.38, 95% CI 1.51-3.74, p=<0.001). Embolic protection device use during saphenous vein graft intervention was associated with improved post-procedural TIMI 2/3 flow (OR 2.38; 95% CI 1.51-3.74; P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: