This is the authors' abstract. We don't add key points for this paper.
A fault indicator, the so-called swing angle, for broken-bar and interturn faults is investigated in this paper. This fault indicator is based on the rotating magnetic-field pendulous-oscillation concept in faulty squirrel-cage induction motors. Using the "swing-angle indicator," it will be demonstrated here that an interturn fault can be detected even in the presence of machine manufacturing imperfections. Meanwhile, a broken-bar fault can be detected under both direct-line and PWM excitations, even under the more difficult condition of partial-load levels. These two conditions of partial load and motor manufacturing imperfections, which are considered as difficult situations for fault detection, are investigated through experimentally obtained test results for a set of 2- and 5-hp induction motors.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Mirafzal et al. (2006) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: