Recent increases in the number of thyroid fine-needle aspiration (FNAs) biopsies and the popularity of on-site evaluation for adequacy (OSEA) have led many practices, including ours, to rely on cytotechnologists for performing OSEA. We retrospectively analyzed the accuracy of a cytotechnologist against that of a cytopathologist in performing OSEA and making the final diagnosis. Of 2,261 thyroid FNA specimens evaluated over a 33-month period under ultrasound guidance with OSEA, the cytotechnologist attended 64.7% (1,462/2,261) of the procedures whereas the cytopathologist attended 35.3% (799/2,261). There was no difference in the adequacy downgrade rate for cytotechnologists compared with that for cytopathologists during this study period (4.1% vs 5.0% downgrade rate, P = .33). Regardless of who rendered the OSEA, subadequate specimens had a higher rate of indeterminate diagnosis (25.2%) than those specimens deemed adequate at the time of OSEA (11.9%, P = .00001). These results indicate that the accuracy of cytotechnologists is comparable with that of cytopathologists in conducting OSEA of the thyroid.
No takes yet. Share an insight, caveat, or question.
Olson et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: