Key result
Total power of systolic arterial pressure variability most sensitively reflected changes in circulating blood volume compared with conventional circulatory parameters in a rabbit model.
Why the study?
Does total power of systolic arterial pressure variability reflect circulating blood volume alterations during hemorrhagic shock and fluid resuscitation in rabbits?
Does total power of systolic arterial pressure variability reflect circulating blood volume alterations during hemorrhagic shock and fluid resuscitation in rabbits?
Total power of systolic arterial pressure variability most sensitively reflects changes in circulating blood volume during hemorrhagic shock and resuscitation in a rabbit model.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for pressure variability in volume assessment; leaves open human validation before any clinical consideration.
Both the high-frequency component of systolic arterial pressure variability and systolic pressure variation (SPV) have been indicated to be strongly affected by respiratory effect and sensitively reflect circulating blood volume (CBV). We attempted to determine the best means reflecting CBV from various parameters using power spectrum analyses of systolic arterial pressure variability (PSSAPV) and heart rate variability (PSHRV), SPV, and pulse pressure variation during graded hemorrhaging and fluid resuscitation. Under isoflurane anesthesia and mechanical ventilation, rabbits in group S (n = 6) had hemorrhaging induced, whereas those in group H (n = 10) had hemorrhaging induced followed by fluid resuscitation. After collecting baseline data, blood was withdrawn at a rate of 1 mL.kg.min for 25 min in both groups, and data were collected at 5 min after bleeding was stopped. Furthermore, in group H, hydroxyethyl starch was continuously infused at a rate of 1 mL.kg.min for 25 min; data were collected at 5 and 60 min after fluid resuscitation. The correlations between CBV and total power (TP, 0.04-2.00 Hz), high-frequency component (0.75-1.40 Hz), and low-frequency component (0.04-0.40 Hz) of PSSAPV were more significant as compared with SPV and pulse pressure variation, whereas no correlations were noted between CBV and PSHRV. To evaluate the regression models appropriately, Akaike information criterion was used, and TP of PSSAPV showed the lowest value. We concluded that TP of PSSAPV most sensitively reflected changes of CBV and that PSSAPV was the most useful parameter for evaluation of volume status as compared with conventional circulatory parameters.
No takes yet. Share an insight, caveat, or question.
Egi et al. (2007) studied Hemorrhagic shock (n=16). Total power of systolic arterial pressure variability (PSSAPV) vs. Systolic pressure variation and pulse pressure variation was evaluated on Correlation with circulating blood volume (CBV). Total power of systolic arterial pressure variability most sensitively reflected changes in circulating blood volume compared with conventional circulatory parameters in a rabbit model.