This paper reports a study of two HTS racetrack coils wound with GdBCO coated conductors, one without turn-to-turn insulation and the other with Nomex insulation. The coils were characterized by charge-discharge, over-current, and sudden discharge tests. Thermal and electrical characteristics of the GdBCO racetrack coil without insulation outperformed the insulated one. The test results confirmed that although the coil without insulation has a slow charging/discharging time constant, the no-insulation winding technique may enable a compact and protection-free racetrack-typed coil with enhanced mechanical integrity as well as better thermal and electrical stabilities.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2011) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: