Answers are grounded in this paper and cite their sources.
In this study, the reversible response ofIcwith uniaxial strain in differently processed GdBCO coated conductor tapes with different substrates has been investigated under self field and magnetic field conditions at 77 K. Higher irreversible strain limit, εirrwas observed in those samples with stainless steel substrate. Additional brass lamination to the Cu-stabilized samples produced enhancement of both εirrand endurable load limit. However, no significant widening of theIc/Ic0-tensile strain window with brass addition was observed in the case of samples having stainless steel substrate. Furthermore, under magnetic field, theIcdegradation behavior was independent on the kind of substrate material, but varied with the kind of manufacturing process adopted. The GdBCO samples showed differentIcpeak positions and degradation behavior depending on the level of magnetic field applied.
No takes yet. Share an insight, caveat, or question.
Shin et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: