Key result
The ecgi2model pipeline reduces activation and repolarization RMSE vs baseline simulations for digital heart twins.
Why the study?
Existing cardiac digital twin pipelines primarily rely on artificial intelligence and optimization to replicate clinical data rather than using it directly as an input.
Does the ecgi2model pipeline reduce the root mean square error of activation and repolarization maps compared to baseline models in digital cardiac twins?
Cohort (n=406)
Does the ecgi2model pipeline reduce the root mean square error of activation and repolarization maps compared to baseline models in digital cardiac twins?
A novel pipeline integrating CMR and ECGI data significantly improves the accuracy of personalized digital cardiac twins, offering a framework for in-silico clinical trials and arrhythmic risk assessment.
Cardiac digital twins may enable precision phenotyping; leaves open prospective validation before clinical adoption.
Background Personalised cardiovascular medicine uses multimodal screening and diagnostic tools, spanning from organ to tissue to molecular levels, to generate a complex and detailed patient phenotype. Cardiac digital twins are powerful tools capable of merging and explore these multimodal data by developing virtual, mechanistic and predictive versions of the patient's heart. State-of-the-art pipelines are mainly based on artificial intelligence and optimization process to replicate clinical data and not used it as an input. We present a proof-of-principle pipeline for building digital heart twins based on cardiovascular magnetic resonance (CMR) imaging and integrated electrocardiographic imaging (ECGI) for diverse clinical scenarios by integrating them into the model (Fig. 1). Methods CMR at 3T was performed on participants all born in the same week in March 1946, as part of the longest-running continued surveillance birth cohort: the National Survey of Health and Development. Cine steady-state free precession end-diastolic frames provided anatomical information per participant while CMR multiparametric mapping and late gadolinium enhancement (LGE) provided tissue characteristics to the electrical myocardial model used in the finite element solver Alya. Lastly, the ECGI activation map was used as a source to define the intrinsic endocardial activation sequence by applying a case-specific correction based on wall thickness and myofibers orientation. Activation-repolarization intervals map was used to introduce the personalised repolarization heterogeneities. Results In total, 406 prospectively recruited participants (77.8 ± 0.1 years, 44% male) had multiparametric CMR with ECGI for digital twin reconstruction. The pipeline’s performance was evaluated by measuring the root mean square error (RMSE) between the ECGI activation and repolarization maps with the in-silico ones obtained without applying the proposed pipeline (Baseline) and after its application (ecgi2model). Results obtained using ecgi2model pipeline presented a significantly reduced activation and repolarization RMSE (Fig. 2b), even providing accurate results in patients with different LGE patterns (Fig. 2c). Conclusion Personalised virtual heart models can be constructed at scale using real-world myocardial structural, functional, and electrical properties, from advanced CMR and ECGI data. Proposed digital twins provide a framework for personalised arrhythmic risk assessment based on real clinical data and also its applicability for in-silico clinical trials. Fig.1 Digital twins pipeline. Fig.2 a) Flattened epicardial map. b) RMSE of activation (ACT), repolarization (RPL) and activation-repolarization intervals (ARI) for the different methods methods. c) ACT and RPL maps obtained from ECGI, baseline simulation and ecgi2model simulation in a healthy participant with normal myocardial tissue, another with subendocardial LGE, and another with subepicardial LGE.Figure 1Figure 2
No takes yet. Share an insight, caveat, or question.
González et al. (2024) reported a cohort. ecgi2model pipeline vs. Baseline simulation without the pipeline was evaluated on Root mean square error (RMSE) between ECGI activation/repolarization maps and in-silico maps. The ecgi2model pipeline significantly reduced activation and repolarization root mean square error compared to baseline simulations for constructing personalized digital heart twins.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: