Key result
A low fluoroscopy protocol for laser balloon pulmonary vein isolation significantly reduced total fluoroscopy time compared to conventional fluoroscopy (1.7 vs 16.9 minutes; P<0.001).
Why the study?
Procedural fluoroscopy usage with laser balloon ablation remains higher than with radiofrequency pulmonary vein isolation approaches due to limited 3-dimensional mapping system integration.
Does a low fluoroscopy protocol reduce fluoroscopy time and radiation exposure compared to conventional approaches in patients undergoing visually guided laser balloon pulmonary vein isolation?
RCT (n=50)
Alternating fashion
Does a low fluoroscopy protocol reduce fluoroscopy time and radiation exposure compared to conventional approaches in patients undergoing visually guided laser balloon pulmonary vein isolation?
A low fluoroscopy protocol for visually guided laser balloon pulmonary vein isolation significantly reduces radiation exposure without compromising procedural efficacy or safety.
Supports low-fluoroscopy protocols for laser balloon PVI to minimize radiation; extends RCT evidence for radiation-sparing AF ablation.
Introduction Although balloon‐based techniques, such as the laser balloon (LB) ablation have simplified pulmonary vein isolation (PVI), procedural fluoroscopy usage remains higher in comparison to radiofrequency PVI approaches due to limited 3‐dimensional mapping system integration. Methods In this prospective study, 50 consecutive patients were randomly assigned in alternating fashion to a low fluoroscopy group (LFG; n = 25) or conventional fluoroscopy group (CFG; n = 25) and underwent de novo PVI procedures using visually guided LB technique. Results There was no statistical difference in baseline characteristics or cross‐overs between treatment groups. Acute PVI was accomplished in all patients. Mean follow up was 318 ± 69 days. Clinical recurrence of atrial fibrillation after PVI was similar between groups (CFG: 19% vs LFG: 15%; P = .72). Total fluoroscopy time was significantly lower in the LFG than the CFG (1.7 ± 1.4 vs 16.9 ± 5.9 minutes; P < .001) despite similar total procedure duration (143 ± 22 vs 148 ± 22 minutes; P = .42) and mean LA dwell time (63 ± 15 vs 59 ± 10 minutes; P = .28). Mean dose area product was significantly lower in the LFG (181 ± 125 vs 1980 ± 750 μGym 2 ; P < .001). Fluoroscopy usage after transseptal access was substantially lower in the LFG (0.63 ± 0.43 vs 11.70 ± 4.32 minutes; P < .001). Complications rates were similar between both groups (4% vs 2%; P = .57). Conclusions This study demonstrates that LB PVI can be safely achieved using a novel low fluoroscopy protocol while also substantially reducing fluoroscopy usage and radiation exposure in comparison to conventional approaches for LB ablation.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2020) conducted an RCT in Atrial fibrillation (n=50). Low fluoroscopy protocol vs. Conventional fluoroscopy protocol was evaluated on Total fluoroscopy time (minutes) (p=<0.001). A low fluoroscopy protocol for laser balloon pulmonary vein isolation significantly reduced total fluoroscopy time compared to conventional fluoroscopy (1.7 vs 16.9 minutes; P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: