Measurements are reported of the current-transfer effect in a 0.58×0.68-mm NbTi (180 filament) copper-matrix wire, and in a 0.33×0.66-mm Nb3Sn (3553 filament) bronze-matrix wire at magnetic fields from 2 to 8 T. With a voltage sensitivity of 100 nV, the effect of current transfer in the copper : NbTi wire was too small to be measured at a distance 1 cm from the current contact. In the bronze : Nb3Sn wire, however, the effect was relatively large and resulted in voltage-current characteristics which had an extensive linear region. The slope of the linear region decreased with distance x from the current contact as x−2±0.3 and reached a value of 10−12 Ω cm, for example, at a distance of 3±0.5 cm. Both the magnitude and functional dependence of the measured current-transfer effects correspond closely to that predicted by theory.
No takes yet. Share an insight, caveat, or question.
Ekin et al. (1978) studied this question.