Answers are grounded in this paper and cite their sources.
In certain critical applications it is current practice to incorporate sealed electron devices within an outer hermetic enclosure for increased seal assurance. An exact solution is now given for the gas influx into such a doubled hermetic enclosure when each enclosure has a given leak size. This solution allows a comparison to be made between the leakage into a single isolated semiconductor package and that into the same package when it is protected by an outer enclosure. If the leaks are in the molecular flow regime, solutions for the pressure within the enclosures are of the formP_i = A_i e-(α - Β)t + B_i e-(α + β)t + P_bfor i = 1,2, where Pbis the external applied pressure at t > 0 andα, constants whose values depend only on the ratios of leak rates and of volumes. The general behavior is described in terms of a merit factor as a measure of the hermetic improvement for doubled enclosures over that of a single enclosure, and characteristics are derived for a broad spectrum of system dimensions. It is shown that a significant improvement in hermeticity over a long time span is not an apriori result of using an outer enclosure.
No takes yet. Share an insight, caveat, or question.
Stanley Ruthberg (1977) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: