Key result
In a real-world registry of patients undergoing PCI, the Excel biodegradable polymer-coated Rapamycin-Eluting Stent demonstrated a 12-month major adverse cardiac event rate of 1.38%.
Why the study?
Does a biodegradable polymer-coated rapamycin-eluting stent with 6-month dual antiplatelet therapy provide safety and efficacy in a real-world PCI population?
Observational (n=654)
Yes
Does a biodegradable polymer-coated rapamycin-eluting stent with 6-month dual antiplatelet therapy provide safety and efficacy in a real-world PCI population?
A biodegradable polymer-coated rapamycin-eluting stent combined with 6 months of dual antiplatelet therapy demonstrated low rates of MACE and no stent thrombosis at 12 months in a real-world Indian PCI registry.
Answers are grounded in this paper and cite their sources.
Supports feasibility with 6-month DAPT in real-world PCI; hypothesis-generating and requires randomized confirmation.
OBJECTIVES: This study aims to assess the safety and efficacy of a biodegradable polymer-coated Rapamycin-Eluting Stent (Excel) used in conjunction with six-month dual antiplatelet therapy in daily practice. BACKGROUND: The polymeric material of cardiac stents has been reported to adversely affect the safety profile of the drug-eluting stents and is also suspected to cause serious long-term complications. It has been proposed that the biodegradable polymer coatings may reduce such late-stage adverse effects. METHODS: This is a prospective, multi-center registry of 654 patients from across 9 cardiology centers in India, who were enrolled and exclusively treated with Excel stents between February 2008 and May 2010. The recommended antiplatelet regimen included clopidogrel and aspirin for 6 months period, followed by lifelong aspirin therapy. RESULTS: The study population included 46.94% diabetics, 24.31% smokers, 48.93% hypertensives and 14.98% hyperlipidemics. The cumulative rates of major adverse cardiac events were 0.153% at discharge and 1.38% at 12 months. The mean percentage of stenosis was 88.24 ± 9.17% No events occurred between 6 and 12 months. CONCLUSIONS: This multi-center registry study on "real world, all comers" has, thus, showed that EXCEL™ stent which is PLA-coated biodegradable Rapamycin-Eluting Stent exhibited high efficacy and safety profile in treatment of patients undergoing PCI as evidenced by significantly lower rates of MACE and no case of stent thrombosis. There was no event even after DAPT was discontinued after 6 months.
No takes yet. Share an insight, caveat, or question.
Hiremath et al. (2014) conducted an observational in Patients undergoing percutaneous coronary intervention (n=654). Excel biodegradable polymer-coated Rapamycin-Eluting Stent was evaluated on Major adverse cardiac events at 12 months. In a real-world registry of patients undergoing PCI, the Excel biodegradable polymer-coated Rapamycin-Eluting Stent demonstrated a 12-month major adverse cardiac event rate of 1.38%.
Synapse has enriched 10 related papers. Consider them for comparative context: