REBCO magnets generate unavoidable screening currents during operation. The screening current effect causes severe damage to both the structural integrity and electromagnetic performance of the coil. Specifically, the screening current induced field (SCIF) leads to distortion and drift in the central magnetic field of the coil. The multifilamentary REBCO stack is a viable structure for suppressing SCIF. However, its complex internal striated architecture incurs high manufacturing challenges and costs. Based on the finite element models proposed with T-A formulation solving the vector potential of current and magnetic, the effect of stacking process and multifilamentary structure are firstly discussed in this research. Then we analyzed the influence of groove layouts on SCIF of multifilamentary stacks. The relevant results show that grooves in high current density regions can interrupt screening current loop and show superior suppressing effect. However, complex groove layout shows significant impact on the distribution of high current density areas under external magnetic field. In this study, we uncovered a phenomenon that adjacent grooves in multifilamentary HTS stack can exhibit an electromagnetic coupling effect. This effect may affect the optimization of groove layout for suppression effect on SCIF and manufacturing costs.