Interfacial reliability of thermoelectric generation (TEG) devices with multilayered material structure is a crucial factor affecting conversion efficiency and device reliability. Previous work demonstrated that specific contact resistivity (ρ c ) between barrier metals/Bi 2 Te 3 interfaces increased with temperature. Furthermore, results showed that the Ti/Bi 2 Te 3 interface had the lowest ρ c at 298 K, whereas the Ni/Bi 2 Te 3 interface exhibited the lowest ρ c at 378 K. To investigate the cause of the temperature dependence of ρ c with barrier metals, we analyzed several interfacial phenomena after the measurement at 298 and 378 K. As a result, Ag diffusion into Bi 2 Te 3, distortion of the barrier metal, and interfacial alloying were observed under the high temperature. These interfacial degradation phenomena were attributed to thermal stresses. Additionally Ag diffusion increased in the order of Ni < Ti < Cr. Therefore, the results of this study provide unique insights into the degradation mechanisms of material interfaces in TEG devices under high-temperature conditions and clarify the relationships between interfacial deterioration and specific contact resistivity increases.