Why the study?
Prone breast radiotherapy spares dose to the heart and lungs, but heart and left anterior descending coronary artery (LAD) dosimetry in hypo-fractionated whole breast radiotherapy with concomitant boost required evaluation and comparison to literature.
Does hypo-fractionated whole breast radiotherapy in the prone position reduce heart and LAD radiation exposure compared to supine techniques in patients with left-side breast cancer?
Does hypo-fractionated whole breast radiotherapy in the prone position reduce heart and LAD radiation exposure compared to supine techniques in patients with left-side breast cancer?
Hypo-fractionated whole breast radiotherapy in a prone setup minimizes radiation exposure to the heart and LAD in patients with left-sided breast cancer.
Answers are grounded in this paper and cite their sources.
Prone WBRT may limit cardiac and LAD exposure in left breast cancer; leaves open prospective validation of clinical outcomes.
Background: Prone breast radiotherapy has been shown to optimally spare the dose to the heart and lungs; we report on the heart and left anterior descending coronary artery (LAD) dosimetry and their implications for current care. Aims: (I) To measure the mean heart dose (MHD) and LAD mean and maximum doses (Dmean and Dmax) in patients with left-side breast cancer who have undergone hypo-fractionated whole breast radiotherapy (WBRT) with a concomitant boost to the post-operative cavity (40.50 Gy to the breast and 48 Gy to the cavity in 15 fractions) in the prone position; (II) to compare the dosimetry results to those reported in the literature for other techniques. Materials and Methods: In a consecutive series of 524 irradiated left-side breast cancer patients, heart and LAD dosimetry data were collected and correlated to breast volume and the volume of the radiation boost to the tumor cavity. A descriptive statistical analysis was performed to compare the same dosimetry data with those reported in the literature from supine techniques. To account for dosimetry differences in hypo-fractionation and conventional fractionated regimens (50–60 Gy in 25–30 fractions) reported in the literature, the cardiac doses were converted to the equivalent dose in 2 Gy fractions (EQD2). As previously reported, the prone setup protocol placed the medial edges of the tangential radiation fields at least 2.5 mm from the contoured LAD. Results: In all patients’ plans, the target coverage was successfully achieved. The mean values (±SD) were as follows: MHD = 0.69 Gy (±0.19) (EQD2 0.35 Gy ± 0.1); LAD Dmean = 2.20 Gy (±0.68) (EQD2 1.18 Gy ± 0.35); LAD Dmax = 4.44 Gy (±1.82) (EQD2 2.55 Gy ± 0.97). The values were consistently lower compared with those achieved by the multiple supine techniques reported in the literature. Spearman’s correlation analysis revealed a strong positive correlation between LAD and heart dosimetry variables. In contrast, no strong correlation was observed between the cardiac dose metrics and breast volume, boost volume, or their ratio index. A linear correlation was detected between LAD Dmean and LAD D2% (R2 0.64); LAD D2% and heart D2% (R2 0.60); LAD Dmax and heart D2% (R2 0.41). Conclusions: The prone position protocol minimizes heart and LAD exposure. This approach results in a dosimetry advantage when compared with more complex and expensive WBRT techniques in the supine position.
No takes yet. Share an insight, caveat, or question.
Gregucci et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: