Answers are grounded in this paper and cite their sources.
A description is given of tests with a high-voltage tube of simple and rugged design. The tube consists essentially of a fiber cylinder extending between the electrodes and evacuated to a pressure of 4×{}10^-6 mm Hg during operation. A potential of 300,000 volts could be maintained on a section of tube 53 cm long. In spite of the fact that the voltage was limited by discharge there was no case of puncture. A simple clear-cut mechanism for the initiation of discharge in vacuum (independent of field currents) is given together with confirming experimental evidence. On this basis there is proposed a method of screening the electrodes to prevent breakdown and permit the application of extremely high voltages to the tube.
No takes yet. Share an insight, caveat, or question.
Atta et al. (1933) studied this question.