Answers are grounded in this paper and cite their sources.
BACKGROUND: Osteogenic growth factors have been suggested to enhance the fixation of implants used in joint replacement. We examined the effect of locally delivered transforming growth factor-beta1 and insulin-like growth factor-1 in a biodegradable poly (D, L-lactide) coating. MATERIAL AND METHODS: In a paired study using 9 dogs, unloaded titanium implants surrounded by a 1-mm gap were inserted into the proximal humerus. The growth factors were incorporated in a poly (D, L-lactide) coating at a 1% (w/w) ratio of TGF-beta1 and a 5% (w/w) ratio of IGF-1. Control implants were uncoated. After 4 weeks, the implants were evaluated by mechanical push-out test and by histomorphometry. RESULTS: A twofold increase was seen in mechanical fixation (strength, stiffness, energy absorption) for the growth factor-treated implants (p = 0.04). Similar results were seen in histomorphometry, as bone ongrowth was 2.5 times higher (p = 0.02), and gap healing was 30-110% higher (p = 0.04) for the growth factor-treated implants than for the control implants. Ongrowth of fibrous tissue was eliminated by the treatment. INTERPRETATION: TGF-beta-1 and IGF-1, locally delivered in a biodegradable poly(D,L-lactide) coating, enhance the mechanical fixation and osseointegration of titanium implants in cancellous bone, and no fibrous tissue is produced in the growth factor treated implants.
No takes yet. Share an insight, caveat, or question.
Lamberg et al. (2006) studied this question.