Key result
HMR1766 increases (S)-warfarin exposure ~3.2-fold vs placebo, potentiating its anticoagulant effect.
RCT (n=18)
Placebo-controlled
Answers are grounded in this paper and cite their sources.
Demonstrates increased warfarin exposure and anticoagulation under HMR1766 in healthy males, suggesting a clinically relevant drug interaction requiring dose adjustments.
HMR1766 is a new nitric oxide (NO)-independent activator of soluble guanylyl cyclase (sGC) in development for the treatment of cardiovascular diseases and chronic heart failure. A significant fraction of patients to be treated with HMR1766 is expected to be maintained on warfarin. Because HMR1766 is an inhibitor and warfarin a substrate of CYP2C9, the authors studied whether warfarin pharmacokinetics and pharmacodynamics are influenced by HMR1766. Eighteen healthy males were to receive a single oral dose of 20 mg warfarin each under steady-state conditions of HMR1766 or placebo. Plasma concentrations of HMR1766, (R)- and (S)-warfarin, and its 7-hydroxy-metabolites were determined using high-performance liquid chromatography and prothrombin time, and the international standardized ratio was determined by the nephelometric method. (S)-Warfarin AUC(inf) and t(1/2) were 106,471 h x microg/L and 82.92 hours versus 33,148 h x microg/L under HMR1766 and 31.72 hours under placebo, and the maximum decrease in prothrombin time values after warfarin dosing was 58.75% versus 39.94%. These data demonstrate a CYP2C9-mediated pharmacokinetic interaction with pharmacodynamic, clinically relevant consequences, which might require warfarin dose adjustment.
No takes yet. Share an insight, caveat, or question.
Oberwittler et al. (2006) conducted an RCT in Healthy males (drug-drug interaction study for cardiovascular diseases and chronic heart failure) (n=18). HMR1766 plus single oral dose of warfarin vs. Placebo plus 20 mg oral warfarin was evaluated on Maximum decrease in prothrombin time values after warfarin dosing (and (S)-warfarin pharmacokinetics). HMR1766 co-administered with warfarin increased (S)-warfarin AUC(inf) (106,471 vs 33,148 h·µg/L) and maximum prothrombin time decrease compared with placebo.
Synapse has enriched 10 related papers. Consider them for comparative context: