Answers are grounded in this paper and cite their sources.
A matched-impedance, low-voltage vacuum-arc centrifuge is described. The centrifuge is a magnetized plasma column, 1 m long, 4 cm in diameter, with ne∼1015 cm−3 and Ti∼3 eV. Rigid rotor frequencies ∼105 rad/s lead to radial, centrifugal separation between isotopes. The source of this rotating plasma column is a vacuum-arc discharge between a negative cathode and a grounded mesh anode at one end of a 2-m-long vacuum chamber. The discharge is driven by an L–C ladder network of 40-mΩ characteristic impedance, which sees the discharge directly as its load, giving a critical damped, flat-topped current pulse of 10-ms duration, with 90% efficient power transfer. An externally applied axial magnetic field, with less than ±1% axial variation, collimates the plasma and induces rotation. Measured cathode erosion rates suggest that such a centrifuge is capable of converting solid into plasma at a rate of 200 mol/day. A piezoelectrically scanned Fabry–Perot interferometer is used to measure ion temperature, Ti, and angular rotation velocity, ω.
No takes yet. Share an insight, caveat, or question.
Prasad et al. (1986) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: