To address this issue, we propose a high-temperature dual-path time-domain synthetic aperture focusing technique (HTDP-SAFT). The method embeds a cubic velocity–temperature model and a direct-wave-envelope-based amplitude scaling factor into the dual-path delay-and-sum kernel. In this way, propagation delay and signal amplitude can be compensated simultaneously during image reconstruction. Experiments show that, at 630 °C, the spatial positioning error (SPI) for 2 mm through-hole and half-through-hole defects in a P91 pipeline is reduced from 9.70–10.40 mm to 0.42–0.49 mm; for a 5 × 2 mm notch defect, the SPI decreases from 3.71 and 9.50 mm at 300 and 630 °C, respectively, to 0.32 and 0.41 mm. Step-size optimization further indicates that a 1 mm scanning step, guided by the spatial Nyquist criterion, is necessary to maintain stable focusing under high-temperature, low-SNR conditions. The proposed approach provides a practically implementable solution for online scanning-based imaging of high-temperature pressurized components.