Experimental design study demonstrates high sensitivity and low nonlinearity in a novel micropressure sensor, highlighting an efficient neural-network-guided fabrication method.
To validate the effectiveness of the grooved diaphragm with back peninsulas and trenches (GDPT) and the radial basis function neural network (RBFNN)-based dimension generator in the development of a 1 kPa piezoresistive micropressure sensor, this paper presents a comprehensive investigation into the design, fabrication, and characterization of the anticipative sensor prototype. The GDPT achieves favorable sensing stress and reduced deflection, enabling a favorable trade-off between sensitivity and nonlinearity; the RBFNN-based generator efficiently determines practicable dimensions for the complex structure, offering a significant improvement over the conventional trial-and-error process. Characterization results demonstrate that the fabricated sensor achieves sensitivity of 13.01 mV/(V·kPa) and nonlinearity of 0.26% FS within the pressure range of 0–1 kPa, in good agreement with the preset design target. This work verifies the validity of the proposed approach and offers a holistic methodology for developing high-performance piezoresistive sensors.