A new cementless tibial baseplate in kinematically aligned total knee arthroplasty has low migration and stabilizes at 3 months: A cohort study using radiostereometric analysis

View Full Paper
Ask AI
Bookmark
Share

Authors

RMRubiana MonteiroAMAli MohammadiANAlexander J. Nedopil

Discussion

Loading...

Member takes

Overview

Cohort study demonstrates low migration and early stabilization of a cementless tibial baseplate in knee arthroplasty, indicating a minimal risk of long-term loosening.

Key Points

  • Determine whether migration of a new cementless tibial baseplate in kinematically aligned total knee arthroplasty remains below the 6-month threshold for long-term loosening and assess when stability occurs.
  • Assessed 45 patients undergoing kinematically aligned total knee arthroplasty with a new cementless tibial baseplate, 38% of whom had a tibial recut.
  • Tracked baseplate migration using model-based radiostereometric analysis postoperatively and at 6 weeks, 3 months, and 6 months.
  • Mean maximum total point motion (MTPM) at 6 months was 0.93 mm, significantly below the 1.15 mm stability threshold (p = 0.015), with stability achieved by 3 months.
  • Baseplate migration showed no correlation with the medial proximal tibial angle (ρ = 0.050, p = 0.77) or hip-knee-ankle angle (ρ = 0.060, p = 0.72).
  • Mean MTPM did not differ between the recut group (0.85 ± 0.56 mm) and the non-recut group (0.97 ± 0.64 mm, p = 0.57).

Cite This Study

Monteiro et al. (2026) studied this question.

synapsesocial.com/papers/6a8563c403308d306e2d710bhttps://doi.org/10.1002/ksa.70572
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1An Insert Goniometer Can Help Select the Optimal Insert Thickness When Performing Kinematically Aligned Total Knee Arthroplasty with a Medial 1:1 Ball-in-Socket and Lateral Flat Surface Insert and Posterior Cruciate Ligament Retention2024 · 3 citations
  2. 2A randomized controlled trial comparing two-year postoperative femoral and tibial migration of a new and an established cementless rotating platform total knee arthroplasty2023 · 21 citations
  3. 3A new tibial insert design with ball-in-socket medial conformity and posterior cruciate ligament retention has low tibial baseplate migration after unrestricted kinematically aligned total knee arthroplasty: a cohort study using radiostereometric analysis2024 · 9 citations
  4. 4Early migration of tibial components is associated with late revision2012 · 210 citations
  5. 5Measurement Error Versus Repeated Measurements: A Guide Describing Two Methods for Computing Bias and Precision of Migration Measurements From Double Examinations Using Radiostereometric Analysis2022 · 12 citations