Answers are grounded in this paper and cite their sources.
A significant factor to be considered in properly designed thyristor converter circuits is dv/dt. The intent of this paper is to analyze a three-phase bridge circuit and show the following. 1) dv/dt faults due to turn-on transients are a threat only for operation in the inverter mode. 2) dv/dt faults due to the thyristor recovery transient are a threat for rectifier operation from about 50 to 0 percent of maximum dc output voltage (a between 60 and 90 degrees) as well as in the inverter mode. 3) dv/dt due to recovery is generally less severe and more easily suppressed than that due to turn-on. 4) Turn-on induced dv/dt can be calculated approximately by the use of simple equivalent circuits. 5) Recovery induced dv/dt can also be calculated if peak reverse current is known. 6) Thyristor critical dv/dt rating at 50 to 60 percent of rated anode voltage may be more useful than present standard ratings.
No takes yet. Share an insight, caveat, or question.
Rice et al. (1968) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: