Why the study?
Does pulmonary autograft aortic root replacement with surgical modifications improve ventricular dimensions and prevent root dilatation in patients with aortic valve disease?
Does pulmonary autograft aortic root replacement with surgical modifications improve ventricular dimensions and prevent root dilatation in patients with aortic valve disease?
Pulmonary autograft aortic root replacement with intraannular positioning and size matching significantly reduces ventricular dimensions early postoperatively.
Answers are grounded in this paper and cite their sources.
May support early remodeling after modified autograft; hypothesis-generating from single case and needs prospective validation.
Pulmonary autograft aortic valve replacement is the only technique for implantation of a biologic, vital and thus nondegenerating valve. The technique of root replacement overcomes problems of asymmetric aortic roots and reduces the risk of malalignment, but bears the risk of dilatation. We have performed pulmonary autograft aortic root replacement in 20 patients (mean age 22 years, range 5-38). Twelve presented with aortic incompetence, 3 with stenosis and 5 with combined defects. Initially roots were implanted just supraannularly with two running suture lines. As the neo-aortic roots gradually dilated, we started to implant autografts intraannulary, but still one valve dilated and aortic incompetence (AI) increased from grade I to II. Consequently the remaining aortic wall was wrapped around the new root and the composite subsequently was reinforced by a circular absorbable mesh. In addition, the aorta and pulmonary valve were exactly sized and the aortic root was reduced by commissuroplasty stitches up to 6 mm in diameter in seven cases. The ventricular size decreased in all patients 10 days after surgery, the left ventricular end-diastolic diameters (LVEDD) from 58 +/- 12 to 52 +/- 10 mm (P = 0.0002; paired t-test) and left ventricular end-systolic diameter (LVESD) from 41 +/- 12 to 36 +/- 10 mm (P = 0.008), but the contractility did not change significantly (fractional shortening from 31 +/- 9% to 30 +/- 9%). The diameter of the new aortic ring increased for the supraannular position but size matching and the intraannular valve position reduced the new ring size significantly (P = 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Domanig et al. (1993) studied this question.