Key result
The instrumented timed up and go test revealed significantly altered gait parameters in FSHD participants compared with normative values (P<0.05) and had excellent reliability (ICC 0.84-0.99).
Why the study?
Does the instrumented timed up and go (iTUG) test reliably measure gait parameters and correlate with disease severity in patients with facioscapulohumeral muscular dystrophy?
Observational
Does the instrumented timed up and go (iTUG) test reliably measure gait parameters and correlate with disease severity in patients with facioscapulohumeral muscular dystrophy?
p-value: p=<0.05
The instrumented timed up and go test is a reliable tool that can distinguish between differing disease severities in facioscapulohumeral muscular dystrophy, suggesting utility for clinical trials.
INTRODUCTION: Instrumenting timed functional motor tasks may reveal a continuum of motor disability that predicts future motor dysfunction. METHODS: We performed a prospective study of the instrumented timed up and go (iTUG) test in genetically confirmed facioscapulohumeral muscular dystrophy (FSHD) participants using a commercially available system of wireless motion sensors. Patients returned within 2 weeks to determine test-retest reliability. Gait parameters in FSHD participants were compared with a normative database, FSHD clinical severity score, manual muscle testing, and patient-reported functional disability. RESULTS: Gait parameters in FSHD participants were significantly (P < 0.05) altered compared with normative values, and reliability was excellent (intraclass correlation coefficient 0.84-0.99). Stride velocity and trunk sagittal range of motion had moderate to strong correlations to other FSHD disease measures. DISCUSSION: The iTUG was reliable, abnormal in FSHD, and could distinguish between participants with differing disease severities. Instrumenting timed functional tasks may prove to be useful in FSHD clinical trials. Muscle Nerve 57: 503-506, 2018.
No takes yet. Share an insight, caveat, or question.
Huisinga et al. (2017) conducted an observational in facioscapulohumeral muscular dystrophy. instrumented timed up and go (iTUG) test vs. normative database was evaluated on Gait parameters (p=<0.05). The instrumented timed up and go test revealed significantly altered gait parameters in FSHD participants compared with normative values (P<0.05) and had excellent reliability (ICC 0.84-0.99).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: