Answers are grounded in this paper and cite their sources.
An evaluation study of x-ray image doses at the Public Hospital Radiological Department sought to determine the causes of the repeat/rejected images and how it is related to the staff expertise. The reasoning behind this study was the maximization of patient safety from excess/unwarranted radiology doses at the department. This article will help develop a mechanism for quality control for the department to make digital x-ray as safe as possible at the facility. This study revealed that positioning error, machine problems, anatomy cutoff, artifacts, and body movement were the reasons for frequent repeat/reject x-ray procedures at the department. This article revealed that these errors had a strong relationship with staff causes. The leading cause of the errors coming up in the radiologic department is directly related to the radiology technologists' causes/competencies. Technologists with less than eight years of experience were directly/indirectly responsible for 87.5% of repeat radiation procedures. Technologists with over eight years of experience contributed to 12.4% of the repeat/rejected procedures. This study recommends implementing quality control methods more aggressively and improving on-the-job staff training to protect patients from unnecessary radiation.
No takes yet. Share an insight, caveat, or question.
Almojadah et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: