Answers are grounded in this paper and cite their sources.
BACKGROUND: We conducted this meta-analysis to compare the outcomes of coaxial microincision cataract surgery (C-MICS) and standard coaxial small incision cataract surgery (C-SICS). METHODS: The outcomes of randomized controlled trials (RCTs) reporting C-MICS and C-SICS were collected from PubMed, Web of Science, and The Cochrane Library in May 2015. The final meta-analysis was conducted on the following intraoperative and postoperative outcomes: ultrasound time (UST), effective phacoemulsification time (EPT), balanced salt solution use (BSS use), cumulative dissipated energy (CDE), mean surgery time, endothelial cell loss percentage (ECL%), best corrected visual acuity (BCVA), increased central corneal thickness (CCT), laser flare photometry values and surgically induced astigmatism (SIA). RESULTS: A total of 15 RCTs, involving 1136 eyes, were included in the final meta-analysis. No significant between-group differences were detected in EPT, BSS use, CDE, BCVA, laser flare photometry values or increased CCT. However, the C-MICS group showed less SIA (at postoperative day 7: p<0.01; at postoperative day 30 or more: p<0.01) and greater ECL% (at postoperative day 60 or more: p<0.01), whereas the C-SICS group required a shorter UST (p<0.01). CONCLUSIONS: The present meta-analysis suggested that the C-MICS technique was more advantageous than C-SICS in terms of SIA, but C-MICS required a longer UST and induced a higher ECL%. Further studies should be done to confirm our results.
No takes yet. Share an insight, caveat, or question.
Shentu et al. (2016) studied this question.