Answers are grounded in this paper and cite their sources.
Precision temperature measurements are required in the LTP, the LISA technology package, for various diagnostics objectives. In this article, we describe in detail the front-end electronics design and the associated temperature sensors to achieve the LTP requirements: noise equivalent temperature of 10 microK Hz(-12) in the frequency range from 1 to 30 mHz at room temperature. We designed an ac Wheatstone bridge and a subsequent digital demodulation to minimize 1/f noise. We show experimental results where the required sensitivity in the measurement bandwidth is fulfilled.
No takes yet. Share an insight, caveat, or question.
Sanjuán et al. (2007) studied this question.