Key result
Continuous thermodilution accurately measures mammary venous blood flow comparable to single-injection and Fick methods.
Answers are grounded in this paper and cite their sources.
The thermodilution method of Fegler, previously used as a single injection technique to measure the flow in one of the main veins draining the mammary gland of goats, has been adapted to a continuous injection technique. Saline at room temperature is injected at rates of 10 to 50 ml/min for 20 to 60 sec and the blood flow is calculated directly from the fall in blood temperature downstream. The method has been checked in vivo by cannulation of the vessel and shown to be as accurate as the single injection technique and the measurement of mammary flow on the Fick principle. It is particularly valuable for determining rapidly the proportion of the mammary venous flow leaving by each of the two main veins.
No takes yet. Share an insight, caveat, or question.
Linzell et al. (1966) studied Mammary venous blood flow in goats. Continuous injection thermodilution with room temperature saline vs. Single injection thermodilution technique and Fick principle was evaluated on Accuracy of mammary venous blood flow measurement. Continuous thermodilution using saline injected at 10-50 ml/min for 20-60 sec accurately measured goat mammary venous blood flow comparable to single injection and Fick methods.