Answers are grounded in this paper and cite their sources.
We perform a detailed comparative study of conventional transverse magneto-optical Kerr effect (T-MOKE) measurements and a methodology that utilizes an effective polarization detection scheme for mixed s- and p-polarized incoming light. To test the ultimate sensitivity of both methods, we also design a series of specialized samples in which the T-MOKE signal of a Co-film is artificially reduced by means of a Ag overcoat of varying thickness. We find that the effective polarization detection scheme leads to a more than 30-fold increase of the T-MOKE signal and signal-to-noise ratio, even under general operation conditions which were not individually optimized. This allowed for the observation of T-MOKE hysteresis loops of Co-films that were buried under 80 nm of Ag, for which the MOKE signal was only 1/600 of that for an uncoated Co-film. In comparison, conventional T-MOKE measurements did not succeed for Ag overcoats thicker than 40 nm.
No takes yet. Share an insight, caveat, or question.
Oblak et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: