Noise and oscillatory behavior of a plasma column produced in front of the microwave discharge neutralizer developed for MUSES-C mission were experimentally investigated. Radiated electric field emissions were measured following to MIL-STD-461 E. The average noise level exceeded the narrowband specification by 30 dBμV/m at frequencies less than 5 MHz. Noise in electron emission current was also measured by using a current probe and a spectrum analyzer, and was compared with the noise of a hollow cathode. The microwave discharge neutralizer generates a broadband noise and oscillations which have a fundamental frequency of about 160 kHz and are accompanied by its harmonics up to the 5th. Considering the dependence on the diameter of the plasma column, they are probably the radial oscillation modes of ion acoustic waves. Although the hollow cathode shows nearly the same noise level at frequencies less than 1 MHz, intense oscillation exists in the 1-10 MHz range, which is generated by the keeper plasma.