Why the study?
The comparative effectiveness and safety of left atrial appendage closure (LAAC) devices, compared with each other and with anticoagulation, is unclear.
Do left atrial appendage closure devices (Amulet or Watchman) improve effectiveness and safety compared to each other or anticoagulation in patients with atrial fibrillation?
Do left atrial appendage closure devices (Amulet or Watchman) improve effectiveness and safety compared to each other or anticoagulation in patients with atrial fibrillation?
The Amulet and Watchman LAAC devices offer similar efficacy for stroke prevention and mortality, but Amulet is associated with a higher risk of pericardial effusion compared to Watchman.
Supports individualized LAAC device selection by anatomy or operator expertise; extends RCT evidence for device equivalence versus anticoagulation in AF.
Introduction Atrial fibrillation‐related stroke is a leading cause of morbidity and mortality. The comparative effectiveness and safety of left atrial appendage closure (LAAC) devices, compared with one another and with anticoagulation, is unclear. Methods We conducted a systematic review and network meta‐analysis (NMA) of all clinical trials comparing the Watchman and Amplatzer Amulet LAAC devices with each other or with warfarin or direct oral anticoagulants (DOACs). The primary comparison was between LAAC devices with secondary comparisons to anticoagulation. The primary effectiveness outcomes were any stroke and all‐cause death. Safety outcomes included any thromboembolism, device embolization, and pericardial effusion. Results There were 476 articles identified from the search and 6 eligible RCTs were included ( n = 3666). There was no difference in the risk of stroke with Amulet versus Watchman (RR = 1.48, 95% CI: 0.64–3.46, I 2 = 41.3%), nor in the risk of death (RR = 1.00, 95% CI: 0.59–1.70, I 2 = 45.0%). Risk of thromboembolism was not significantly different with Amulet versus Watchman (RR = 0.73, 95% CI: 0.18–2.97, I 2 = 0%), nor was risk of device embolization (RR = 2.29, 95% CI: 0.71, 7.43, I 2 = 0%). Both devices exhibited increased risk of pericardial effusion compared with warfarin, with Amulet at highest relative risk (RR = 27.08, 95% CI: 3.53–207.98, I 2 = 0%) followed by Watchman (RR = 12.79, 95% CI: 1.73–94.85, I 2 = 0%). Amulet also carried higher relative risk of pericardial effusion than Watchman (RR = 2.12, 95% CI: 1.45–3.09). Conclusion In this NMA, the Amulet and Watchman LAAC devices were associated with similar risks for stroke, mortality, thromboembolism, and device embolization. Pericardial effusion risk was higher with Amulet than Watchman.
No takes yet. Share an insight, caveat, or question.
Davis et al. (2025) studied this question.