Answers are grounded in this paper and cite their sources.
The control structure of a PWM (pulsewidth modulation) inverter-fed sinusoidal synchronous motor commonly includes two or three current control loops. Previous simulation studies have shown that the three-loop structure should be preferred: hence the neutral-point voltage can move freely. To obtain the same results with the two-loop structure, a more complex control variable limitation strategy is compulsory. However, the three-loop structure is very sensitive to imperfections in the control system (gain errors and offsets). Simulation and experimental results for both structures are compared and the influence of a neutral-point voltage (NPV) feedback loop to cancel homopolar errors in the three-loop structure is discussed.>
No takes yet. Share an insight, caveat, or question.
Baudon et al. (1992) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: