Data on field-reversal experiments in the neutral-beam-injected 2XIIB mirror machine are reported. The best result is an estimated field-reversal parameter ζ = ΔB/B vac = 0.9 ± 0.2 with vacuum field strength B vac = 4.35 kG. Experiments at higher field strength B vac = 6.7 kG achieved ζ = 0.6 ± 0.1. Ion energy confinement ⟨nτ Ei ⟩ for the B vac = 6.7 kG experiment is less than that predicted by classical Spitzer electron drag. Ion-cyclotron oscillations increasing with injected neutral-beam current suggest that ion-cyclotron losses are present and that ΔB/B vac could be increased by improving stabilization of the ion-cyclotron oscillations.