Answers are grounded in this paper and cite their sources.
An electromagnetic T tube was the source of a plasma used to measure line profiles of singly ionized atoms. The profiles of C II lines emitted by a plasma composed of He and CO₂ in the ratio 95:5 were scanned with a monochromator. The profile scans were accomplished by repeated firings of the T tube while advancing the monochromator in wavelength steps. Also measured was the profile of the 3934 {} Ca II resonance line emitted by a plasma composed of He, H₂, and CO₂ in the ratio 20:10:70 with Ca as an impurity. The profile of the 3889 {} He I line was also measured and its halfwidth was used to determine the plasma electron density in the case of the C II lines. Likewise H_α was used to determine the electron density in the case of the Ca II line. The experimental C II and Ca II Stark-profile half-widths were compared with the theoretically calculated values.
No takes yet. Share an insight, caveat, or question.
Roberts et al. (1967) studied this question.