Magnetocardiography in a canine model of experimental myocardial infarction revealed that S-T segment shifts are not produced by direct currents.
S-T shifts on magnetocardiography arise independently of direct currents after infarction; leaves open their mechanism for human studies.
Magnetocardiograms with a bandwidth of 0 to 40 hertz were recorded from intact dogs undergoing myocardial infarction. This was done with a superconducting magnetometer in a magnetically shielded room. The purpose was to look for the steady currents of injury from the heart which supposedly produce much of the S-T segment shifts during infarction. These heart currents cannot be measured with surface electrodes because of direct-current interference from other sources, such as from the contact potential between electrode and skin. The magnetocardiograms showed both S-T segment shifts and direct currents as a result of infarction. However, they also showed that the S-T segment shifts were not produced by the direct currents. It is unlikely that these direct currents originated from the infarcted area, and their exact origin is not yet known.
No takes yet. Share an insight, caveat, or question.
Cohen et al. (1971) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: