A back electromotive force-based position observer for motion-sensorless synchronous reluctance motor (SyRM) drives is augmented with high-frequency signal-injection method for improved low-speed operation. Previously proposed observer structure is further improved to account for the cross saturation in the motor. The combined observer is experimentally evaluated using a 6.7-kW SyRM drive in low-speed operation and under various load conditions. The resulting position error at low speeds and standstill is small.
No takes yet. Share an insight, caveat, or question.
Tuovinen et al. (2014) studied this question.