Key result
High-flow lung perfusion worsens compliance loss by an absolute ~15% during high-pressure ventilation vs lower flow.
RCT (n=21)
Randomized
Answers are grounded in this paper and cite their sources.
To investigate whether the magnitude of blood flow contributes to ventilator-induced lung injury, 14 sets of isolated rabbit lungs were randomized for perfusion at either 300 (Group A: n = 7) or 900 ml/ min (Group B: n = 7) while ventilated with 30 cm H2O peak static pressure. Control lungs (Group C: n = 7) were ventilated with lower peak static pressure (15 cm H2O) and perfused at 500 ml/min. Weight gain, changes in the ultrafiltration coefficient (DeltaKf) and lung static compliance (CL), and extent of hemorrhage (scored by histology) were compared. Group B had a larger decrease in CL (-13 +/- 11%) than Groups A (2 +/- 6%) and C (5 +/- 5%) (p < 0.05). Group B had more hemorrhage and gained more weight (16.2 +/- 9.5 g) than Groups A (8.7 +/- 3.4 g) and C (1.6 +/- 1.0 g) (p < 0.05 for each pairwise comparison between groups). Finally, Kf (g . min-1 . cm H2O-1 . 100 g-1) increased the most in Group B (DeltaKf = 0.26 +/- 0. 20 versus 0.17 +/- 0.10 in Group A and 0.05 +/- 0.04 in Group C; p < 0.05 for B versus C). We conclude that the intensity of lung perfusion contributes to ventilator- induced lung injury in this model.
No takes yet. Share an insight, caveat, or question.
Broccard et al. (1998) conducted an RCT in Ventilator-induced lung injury (n=21). High-flow lung perfusion with high-pressure ventilation vs. Low-flow perfusion (300 ml/min with 30 cm H2O pressure) or control (500 ml/min with 15 cm H2O pressure) was evaluated on Change in lung static compliance (CL), weight gain, ultrafiltration coefficient (DeltaKf), and hemorrhage (p=<0.05). High-flow lung perfusion during high-pressure ventilation caused greater compliance loss and weight gain than 300 ml/min perfusion.
Synapse has enriched 10 related papers. Consider them for comparative context: