Why the study?
Macintosh intubation causes significant hemodynamic changes that can be life-threatening in vulnerable patients, leading to the hypothesis that the Glidescope produces fewer hemodynamic effects and postoperative complications.
Does the Glidescope laryngoscope reduce hemodynamic stress responses compared to the Macintosh laryngoscope in adult hypertensive patients undergoing endotracheal intubation?
Does the Glidescope laryngoscope reduce hemodynamic stress responses compared to the Macintosh laryngoscope in adult hypertensive patients undergoing endotracheal intubation?
In adult patients with controlled hypertension, the use of a Glidescope for endotracheal intubation significantly reduces hemodynamic stress responses and postoperative complications compared to a Macintosh laryngoscope.
Answers are grounded in this paper and cite their sources.
Favors Glidescope for intubation in hypertensive patients; extends RCT evidence to this high-risk group.
Background Endotracheal intubation with the Macintosh has been associated with difficult visualization of the glottis, difficult intubation, high force,extensive manipulation with significant hemodynamic changes, which may be life threatening in vulnerable patients. We assume that Glidescope has less hemodynamic effects and less postoperative complication.Methods Ninety eligible patients with controlled hypertension were randomly allocated into two groups with 45 patient in each group, G group for the Glidescope and M group for the Macintosh. Both groups were compared for hemodynamic changes including systolic, diastolic, mean blood pressure, heart rate as primary outcome while first attempt success rate, number of attempts, Cormack Lehane score, postoperative sore throat, hoarseness of voice and airway injury as secondary outcome.Results Analysis of hemodynamic changes showed that the Glidescope decreased hemodynamic response to endotracheal intubation in controlled hypertensive patients with better intubation condition using Cormack Lehane score, first attempts success rate and number of needed trials compared to Macintosh laryngoscope. Also, Glidescope showed less post operative complications as sore throat and hoarseness of the voice; meanwhile, no airway injury happened in both groups. However, Glidescope needed more time for completion of intubation.Conclusions It could be concluded that using the Glidescope for endotracheal intubation in controlled hypertensive patients in comparison to Macintosh was associated with significant decrease in hemodynamic stress responses, decreased incidence of postoperative sore throat and hoarseness of voice and it improved the endotracheal intubation process.
No takes yet. Share an insight, caveat, or question.
Hayes et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: